DC/DC Converter
TEN 50WI Series, 50 Watt
•
Very high power density:
50 W in 1” x 2” x 0.4” package
•
•
•
Wide 4:1 input range
•
•
•
•
•
Protection against over-temperature
Excellent efficiency up to 92 %
Operating temperature range
–40°C to +80°C
UL 62368-1 IEC 62368-1
The TEN 50WI Series is a range of isolated high performance DC/DC converter
modules. With a very high efficiency of up to 92% and the use of highest reliable components these 50 W converters can be packed into the standard 1.0”
x 2.0” casing. The 10 models have a wide 4:1 input voltage range and a tight
output voltage regulation. They do not need a minimum load and offer a high
efficiency also at low load conditions. The output voltage is adjustable by external resistor. Remote On/Off and protection against overload and short circuit
are standard features of these converters. Typical applications are in mobile
equipment, instrumentation, distributed power architectures in communication
and industrial electronics and everywhere where space on the PCB is critical.
Output voltage adjustable
Remote On/Off
I/O isolation 1500 VDC
3-year product warranty
Models
Order Code
Input Voltage
Output Voltage
Output Current
Efficiency
Range
nom. (adjustable)
max.
typ.
TEN 50-2410WI
3.3 VDC (2.97 - 3.63 VDC)
10'000 mA
90 %
TEN 50-2411WI
5 VDC (4.5 - 5.5 VDC)
10'000 mA
91 %
12 VDC (10.8 - 13.2 VDC)
4'170 mA
92 %
15 VDC (13.5 - 16.5 VDC)
3'330 mA
92 %
9 - 36 VDC
(24 VDC nom.)
TEN 50-2412WI
TEN 50-2413WI
TEN 50-2415WI
24 VDC (21.6 - 28.8 VDC)
2'080 mA
91 %
TEN 50-4810WI
3.3 VDC (2.97 - 3.63 VDC)
10'000 mA
90 %
TEN 50-4811WI
18 - 75 VDC
(48 VDC nom.)
TEN 50-4812WI
TEN 50-4813WI
TEN 50-4815WI
5 VDC (4.5 - 5.5 VDC)
10'000 mA
91 %
12 VDC (10.8 - 13.2 VDC)
4'170 mA
92 %
15 VDC (13.5 - 16.5 VDC)
3'330 mA
92 %
24 VDC (21.6 - 28.8 VDC)
2'080 mA
91 %
Options
TEN-HS6
- Optional Heat Sink: www.tracopower.com/products/ten-hs6.pdf
www.tracopower.com
September 20, 2023
Page 1 / 4
TEN 50WI Series, 50 Watt
Input Specifications
Input Current
24 Vin models: 80 mA typ. (3.3 Vout model)
60 mA typ. (5 Vout model)
80 mA typ. (12 Vout model)
80 mA typ. (15 Vout model)
80 mA typ. (24 Vout model)
48 Vin models: 40 mA typ. (3.3 Vout model)
30 mA typ. (5 Vout model)
60 mA typ. (12 Vout model)
60 mA typ. (15 Vout model)
50 mA typ. (24 Vout model)
24 Vin models: 1'528 mA typ. (3.3 Vout model)
2'290 mA typ. (5 Vout model)
2'267 mA typ. (12 Vout model)
2'263 mA typ. (15 Vout model)
2'286 mA typ. (24 Vout model)
48 Vin models: 764 mA typ. (3.3 Vout model)
1'145 mA typ. (5 Vout model)
1'134 mA typ. (12 Vout model)
1'134 mA typ. (15 Vout model)
1'143 mA typ. (24 Vout model)
24 Vin models: 50 VDC max. (100 ms max.)
48 Vin models: 100 VDC max. (100 ms max.)
24 Vin models: 7.5 VDC typ.
48 Vin models: 16 VDC typ.
24 Vin models: 40 mAp-p typ.
48 Vin models: 30 mAp-p typ.
24 Vin models: 1'000 mA (slow blow)
48 Vin models: 500 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal LC-Type
- At no load
- At full load
Surge Voltage
Under Voltage Lockout
Reflected Ripple Current
Recommended Input Fuse
Input Filter
Output Specifications
Output Voltage Adjustment
See application note:
Voltage Set Accuracy
Regulation
Ripple and Noise
(20 MHz Bandwidth)
Capacitive Load
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
Minimum Load
Temperature Coefficient
Start-up Time
–10% to +20% (24 Vout models)
±10% (other single models)
(By external trim resistor)
www.tracopower.com/overview/ten50wi
Output power must not exceed rated power!
±1% max.
0.5% max.
0.5% max.
100 mVp-p max. (w/ 1 µF MLCC || 10 µF TC)
100 mVp-p max. (w/ 1 µF MLCC || 10 µF TC)
150 mVp-p max. (w/ 1 µF MLCC || 10 µF TC)
150 mVp-p max. (w/ 1 µF MLCC || 10 µF TC)
150 mVp-p max. (w/ 1 µF MLCC || 10 µF TC)
26'000 µF max.
17'000 µF max.
3'000 µF max.
2'000 µF max.
750 µF max.
Not required
±0.02 %/K max.
30 ms max. (Power On)
30 ms max. (Remote On)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 4
TEN 50WI Series, 50 Watt
Short Circuit Protection
Output Current Limitation
Transient Response
Continuous, Automatic recovery
150% typ. of Iout max.
3% typ. / 5% max. (75% to 100% Load Step)
250 µs typ. (75% to 100% Load Step)
- Response Deviation
- Response Time
Safety Specifications
Safety Standards
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/ten50wi
PD 3
Not mains connected
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
Over Voltage Category
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
External filter proposal:
- Conducted RF Disturbances
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
FCC Part 15 class A (with external filter)
EN 55032 class A (with external filter)
FCC Part 15 class A (with external filter)
www.tracopower.com/overview/ten50wi
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
www.tracopower.com/overview/ten50wi
EN 61000-4-6, 10 Vrms, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
- Operating Temperature
Power Derating
- Case Temperature
- Storage Temperature
- High Temperature
Over Temperature
Protection Switch Off
Cooling System
Remote Control
95% max. (non condensing)
–40°C to +80°C
–40°C to +85°C (with Heat Sink)
+105°C max.
–50°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/ten50wi
110°C typ.
- Protection Mode
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
- Input to Output, 60 s
- Input to Output, 1 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
Natural convection (20 LFM)
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
2.5 mA typ.
-0.5 to 0.5 mA
6'000 m max.
285 kHz typ. (PWM)
Functional Insulation
1'500 VDC
1'800 VDC
1'000 MΩ min.
2'200 pF max.
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 4
TEN 50WI Series, 50 Watt
Reliability
Washing Process
- Calculated MTBF
230'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
Alu alloy, black anodized coating
Non-conductive FR4 (UL 94 V-0 rated)
Epoxy (UL 94 V-0 rated)
Copper Alloy (C6801)
Nickel (2.5 µm min.)
Gold (75 - 125 nm), glossy
Metal Case
PCB Mount
THD (Through-Hole Device)
2" x 1"
Lead-Free Wave Soldering
260°C / 10 s max.
34 g
- Case to Ambient
12 K/W typ.
10 K/W typ. (with Heat Sink)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
cb619863-d838-4b4f-a2ec-b819f3151448
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/ten50wi
2.54
5
3
3.6 (0.14)
1.85 (0.073)
(0.400)
Bottom view
Pinout
25.4 (1.00)
(0.400)
10.16
2
(0.400)
4
1
10.16 10.16
5.08
(0.200)
50.8 (2.00)
(0.100)
Outline Dimensions
6
11.0
(0.43)
5.5
(0.22)
45.72 (1.800)
Pin
Single
1
+Vin (Vcc)
2
–Vin (GND)
3
Remote On/Off
4
+Vout
5
–Vout
6
Trim
Ø1.0 (Ø0.04)
Dimensions in mm (inch)
Tolerances: x.x ±0.25 (x.xx ±0.01)
x.xx ±0.13 (x.xxx ±0.005)
Pin diameter tolerances: x.x ±0.05 (x.xx ±0.002)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 4 / 4
很抱歉,暂时无法提供与“TEN 50-4815WI”相匹配的价格&库存,您可以联系我们找货